What was found
DURING INSPECTION OF DATUM ACFT IAW EO 4753B328, A CRACK WAS FOUND ON AT BS 880, LT SIDE TENSION TIE STR 9L, AFT CHANNEL AT HOLE NR 16 FIG 1 CRACK LENGTH WAS 0.040" AND RUNNING INBD AT 9 O'CLOCK. THE DAMAGED TENSION TIE WAS REPAIRED IAW WORK STEP 23D OF PART 1 OF EO 4753B328. THE SUBJECT DAMAGE WAS DOCUMENTED ON NRC 501948. THE DAMAGED TENSION TIE WAS REPAIRED IAW WORK STEP 23 D OF PART 1 OF EO 4753B328. AS PER WORK STEP 23 D OF PART 1 OF THE EO, THETENSION TIE CRACKS THAT CANNOT BE REMOVED BY DOING THE OVERSIZE HOLE REPAIR, SHOULD BE REPAIRED AS GIVEN IN SRM 53-10-11, FIG 2.