What was found
DECK FRAME AT BS 760 BETWEEN S-5L AND S-7L FOUND CRACKED AND WAS FOUND DURING THE SECTION 42 UPPER LOBE INSP ACCOMPLISHED IAW EO 4753A165, REV C (SB 747-53-2349 REV 3, AD 2009-18-07). THE CRACK WAS LOCAL ONLY TO THE FRAME AND WAS LOCATED AT S-6L. THE CRACK WAS APPROX 0.5" INCH IN LENGTH. THE SUBJECT DAMAGE WAS RECORDED ON NRC 511491. THE CRACKED WEB WAS REPAIRED IAW SRM 53-10-04, FIG 54 DETAIL IV. THE SRM REPAIR STOP DRILLS THE CRACK AND INSTALLS A DOUBLER OVER THE AREA.