What was found
FRAME AT BS 760 BETWEEN S-5R AND S-7R FOUND CRACKED AND WAS FOUND DURING THE SECTION 42 UPPER LOBE INSPECTION ACCOMPLISHED IAW EO 4753A165, REV C (SB 747-53-2349 REV 3, AD 2009-18-07). THE CRACK WAS LOCAL ONLY TO THE FRAME PN AND WAS LOCATED AT S-6R. THE CRACK WAS APPROX 0.75 INCH IN LENGTH. THE SUBJECT DAMAGE WAS RECORDED ON NRC 511483. THE CRACKED WEB WAS REPAIRED IAW SRM 53-10-04, FIG 54. THE SRM REPAIR STOP DRILLS THE CRACK AND INSTALLS A DOUBLER OVER THE AREA.