What was found
DURING INSPECTION, IAW EO 4453A301 REV A, CRACK WAS FOUND AT 1 EA FASTENER HOLE ON AT BS 860 RT SIDE TENSION TIE (STR 9R), AFT CHANNEL. THE SUBJECT DAMAGE WAS DOCUMENTED ON NRC 50599. THE DAMAGED TENSION TIE WAS REPAIRED IAW WORK STEP 11E OF PART 2 OF EO 4753B301, REV A IAW WORK STEP 11E OF PART 2 OF EO, THE TENSION TIE CRACKS THAT CANNOT BE REMOVED BY DOING THE OVERSIZE HOLE REPAIR, SHOULD BE REPAIRED AS GIVEN IN SRM 53-20-30, REPAIR 1.