What was found
DURING INSPECTION IAW EO 4453A301, REV A, 1 EA CRACK WAS FOUND ON AT BS 820 RT SIDE TENSION TIE (STR 10R), AFT CHANNEL. (THE DAMAGED TENSION TIE WAS REPAIRED IAW WORK STEP 9E OF PART 2 OF EO 4753B301REV A. IAW WORK STEP 9E OF PART 2 OF EO, THE TENSION TIE CRACKS THAT CANNOT BE REMOVED BY DOING THE OVERSIZE HOLE REPAIR, SHOULD BE REPAIRED AS GIVEN IN SRM 53-20-30, REPAIR 1.)