What was found
DURING INSP OF DATUM ACFT IAW EO 4453A301REV A, CRACKS WERE FOUND AT 2 EA FASTENER HOLES ON AT BS 760 RT SIDE TENSION TIE (STR 10R), AFT CHANNEL. (THE DAMAGED TENSION TIE WAS REPAIRED IAW WORK STEP 6E OF PART 2 OF EO 4753B301, REV A IAW WORK STEP 6E OF PART 2 OF EO, THE TENSION TIE CRACKS THAT CANNOT BE REMOVED BY DOING THE OVERSIZE HOLE REPAIR, SHOULD BE REPAIRED AS GIVEN IN SRM 53-20-30, REPAIR 1.)