What was found
DURING VOR ANTENNA REPLACEMENT, DISCOVERED THE VERTICAL STABILIZER - FIN WL339.5 SUSTAINED LIGHTNING STRIKE CAUSING DAMAGE TO THE VOR ANTENNA AND TO THE RT SIDE OF THE VERTICAL STABILIZER EXTERNAL SKIN CONSISTING OF A HOLE/PUNCTURE MEASURING 1.3 INCHES DIAM. (REF FIGURE 1). THE DAMAGE IS BEYOND THE LIMITS OF SRM 51-40-06, FIGURE 1 (DISPOSITION WAS MADE TO PERFORM A TIME LIMITED REPAIR AS DESCRIBED IN PART 1 WORK INSTRUCTIONS; SCHEDULE REPEAT INSPECTIONS AT EVERY 10 FC (FLIGHT CYCLES) AND PERMANENT REPAIR PRIOR TO THE ACCUMULATION OF 2,000 FH (FLIGHT HOURS) AFTER PART 1, IAW SRM 51-40-00.)