What was found
DURING WALKAROUND INSPECTION, MX FOUND THE RT WING GEAR DOOR FAIRING - LOWER EDGE CRACKED, MEASURING 3.0 IN. X 1.5 IN (REF FIG 1). DAMAGE FOUND TO BE BEYOND THE SRM 52-80-02, FIG 101 ALLOWABLE DAMAGE 4 LIMITS IAW SRM 51-70-02, FIG 101 SHEET 9 OF 41. REPAIRED IAW SRM 51-70-17 OR SRM 51-70-07.