What was found
DURING WALKAROUND INSPECTION, MX FOUND RT HORIZONTAL STABILIZER AFT TIP PUNCTURED AND DAMAGED (REF FIG 1), MEASURING 0.5625 IN. X 0.375 IN. X 0.1875 IN DEPTH INTO THE AFT FAIRING CORNER. DAMAGE IS BEYOND LIMITS IAW THE SRM 55-10-01, FIG 101, TABLE I DETAIL V. DAMAGE TO THE RT HORIZONTAL STABILIZER AFT TIP PUNCTURE IS BEYOND THE LIMITS IAW SRM 55-10-30F FIG 101. REPAIRED IAW SRM 55-10-30, FIG 201, REPAIR 1.