What was found
LEFT AC BUSS INTERMITTENT ON ENGINE SHUTDOWN. FOUND LT GENERATOR CONTROL CIRCUIT BREAKER T-1 CONTACT OPEN DURING FAULT. R & R LT GENERATOR CONTROL CIRCUIT BREAKER IAW AMM 24-22-03, SYS OPS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEFT AC BUSS INTERMITTENT ON ENGINE SHUTDOWN. FOUND LT GENERATOR CONTROL CIRCUIT BREAKER T-1 CONTACT OPEN DURING FAULT. R & R LT GENERATOR CONTROL CIRCUIT BREAKER IAW AMM 24-22-03, SYS OPS CHECKED GOOD.