As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DAMAGE FOUND TO SECTION 46 MAIN DECK - FLOORBOARD BS 2060 - LBL 5.0 TO RBL 5.0 GOUGED AND DELAMINATION DAMAGE. THE GOUGED AREA MEASURES APPROX 12.0 IN. X 5.0 IN. DAMAGE IS BEYOND THE SRM 53-00-50, FIG 101. ALLOWABLE DAMAGE 1 LIMITS, DUE TO ITS LOCATION: DAMAGE IS NOT PERMITTED WITHIN 3.0" OF THE FLOOR PANEL EDGE. PERFORMED A TIME LIMITED REPAIR IAW EO 4453A774.