What was found
DURING A CHECK INSPECTION OF THE DATUM ACFT, FOUND A SMALL PUNCTURE ON THE RT WING LANDING GEAR - DOOR SKIN. THE DAMAGE AREA FALLS IN THE CRITICAL AREA OF SRM 52-80-02-01-01. ALLOWABLE DAMAGE GENERAL. THE SRM DOESN'T PROVIDE THE ALLOWABLE LIMITS ON THIS AREA. IT INSTRUCTS TO CONTACT MFG FOR THE DATA. (PERFORM A TIME LIMITED REPAR AS DESCRIBED IN PART 1 WORK INSTRUCTIONS, SCHEDULE REPEAT INSPECTIOS AT EVERY 25 FC AFTER PART 1 AND PERMANENT REPAIR PRIOR TO OR AT THE NEXT C CHECK AFTER PART 1 HAS BEEN ACCOMPLISHED IAW SRM 51-70-17.)