What was found
AFTER ENG START EICAS MESSAGE L PACK TEMP RECEIVED, RAN CHECKLIST AS REQUIRED. PERFORMED BITE ON LT PACK CONTROLLER, FAULTED RAM EXHAUST ACTUATOR, RESET LT PACK CONTROLLER & PERFORMED TEST ON LT PACK EXHAUST ACTUATOR IAW AMM 21-53-02, OPERATION IS NORMAL. AFTER TEST, PERFORMED ANOTHER BITE OF LT PACK CONTROLLER, NO FAULTS PRESENT.