As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SDR UIEA2014071800338. LIGHTNING STRIKE AT 12 O'CLOCK POSITION. EO4853A013 DOCUMENTS & APPROVES THE CAT. A PERMANENT REPAIR TO THE PSE & FCBS STRUCTURE DAMAGED BY THIS EVENT. THIS EO DOCUMENTS & APPROVES THE RIVET REPAIRS ACCOMPLISHED WHETHER THEY ARE REPLACEMENT OR HOLE PLUG RIVETS, ACCOMPLISHED IAW PROCEDURES DEFINED IN SRM 53-00-01-2R-9.