What was found
FOUND MAIN DECK FLOORBEAM CORROSION AT STATION 1580, RBL 95. REPAIRED DAMAGED AREA IAW SRM 53-00-51-2R-3 REPAIR 3 REV 71. JOB COMPLETED & CONDITION CHECKED NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND MAIN DECK FLOORBEAM CORROSION AT STATION 1580, RBL 95. REPAIRED DAMAGED AREA IAW SRM 53-00-51-2R-3 REPAIR 3 REV 71. JOB COMPLETED & CONDITION CHECKED NORMAL.