What was found
NUMBER 8 FLAP 1, 2, 3 BEAM HAS DEFECT ON THE .0620 INCH HOLE, DURING HFEC OPEN HOLE SCAN. REPAIRED HOLE TO REMOVE DEFECT & INSTALLED SERVICEABLE BUSHING IAW SRM 51-40-02, CMM 27-51-97 & REA 47136REA12.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NUMBER 8 FLAP 1, 2, 3 BEAM HAS DEFECT ON THE .0620 INCH HOLE, DURING HFEC OPEN HOLE SCAN. REPAIRED HOLE TO REMOVE DEFECT & INSTALLED SERVICEABLE BUSHING IAW SRM 51-40-02, CMM 27-51-97 & REA 47136REA12.