What was found
ON FINAL, RT WING GEAR DOOR INDICATED NOT DOWN WITH ALL OTHER INDICATIONS NORMAL. RECYCLED, NORMAL INDICATIONS, STATUS GEAR MONITOR. SENSOR VISUAL CONDITION CHECK OK. PSEU BITE TEST PASSED IAW AMM 32-61-00-501. SENSOR TO TARGET GAP CHECKED OK IAW AMM 32-61-32 206. SENSOR WIRE HARNESS CONDITION CHECK OK AROUND WW, CONT TO LP 722504. R & R PSEU IAW AMM 32-09-03-401. GND TEST PASSED NO FAULT.