What was found
REPAIR CORROSION ON THE WING INTER SPAR LOWER SKIN, PANEL NR 3, LOWER SIDE NEAR FSS 1305. BLENDED OUT THE DAMAGED AREA, MEASURED & REWORKED. THE DEEPEST THICKNESS WAS 0.216 INCHES, WHICH WAS NOT ALLOWABLE IAW SRM 57-20-01, ALLOWABLE DAMAGES FIG 101 CHART I REV 32. DETAIL DATA REF TO IC ATTACHING SHEET NR 0069558 & NRC DATA SHEET CONTROL NR 050079 & CONTACT PE TO DO FURTHER ACTIONS. PEM EI NR T2015 57B-2573 REV 1 JOB COMPLETED & CONDITION CHECKED NORMAL.