What was found
CORROSION, SKIN AT HST RT LOWER EXTERNAL SKIN, REAR SPAR STAB STATION 255. REMOVE DAMAGE & MEASURE REWORK AREA LENGTH=1" & WIDTH=0.5" & DEPTH=0.007" IS WITHIN ALLOWABLE LIMITS IAW SRM 55-10-01-1A-1. ALLOWABLE DAMAGE 1 REV 32 & FREE OF CORROSION, DETAIL DATA IAW JOB CARD ATTACHING SHEET NR 0069640. PFM REWORKED AREA PROTECTIVE TREATMENT IAW SRM 51-20-01 REV 32. CONDITION CHECKED NORMAL & JOB COMPLETED.