What was found
ON TAXI, EICAS WARNING MSG, FIRE MAIN DECK AFT, DISPLAYED. ACCOMPLISHED CHECKLIST, WALK THROUGH BY LOADMASTER, CONFIRMED & FALSE CONDENSATION. ACCOMPLISHED FIRE & OVERHEAT DETECTION SYS OPERATIONAL TEST IAW MM 26-10-00-715-001. ALL TEST PASSED, NO MSGS DISPLAYED. OK FOR SERVICE.