FOUND MD FLOORBEAM CORROSION AT STATION 2240, LBL 69 - 86. REPAIRED DAMAGED AREA IAW SRM 53-00-51 REPAIR 3 & REV 75. JOB COMPLETED & CORROSION CHECKED NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND MD FLOORBEAM CORROSION AT STATION 2240, LBL 69 - 86. REPAIRED DAMAGED AREA IAW SRM 53-00-51 REPAIR 3 & REV 75. JOB COMPLETED & CORROSION CHECKED NORMAL.