As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION WEB RT WING LG & WW, CTR FUEL TANK REAR SPAR, STATION 1224 & RBL 94. REMOVED GND WIRE FOR ACCESS REFER TO JC ATTACHING SHEET NO 0062331. BLEND OUT CORROSION AREA IAW SRM 51-10-02-0O-0 REV 75. PFM NOT INSPECTED & DETAIL DATA REFER TO JC ATTACHING SHEET NO 0062354. ACCOMPLISHED EI NO T2016A57M-516 REV. INSTALLED GND WIRE REFER TO JC ATTACHING SHEET NO 0062331. JOB COMPLETED & CONDITION CHECKED NORMAL.