What was found
ON MX WALK AROUND, FOUND RT INBD TE FLAP DAMAGE, NR 5 & 6 CANOE FAIRINGS DAMAGED, AFT FLAP & CAM SYS ROD TO TE FLAP SYS FAILED IN PROCESS OF ACCOMPLISHING ALL REQUIRED REPAIRS. TE FLAP TRACK FAIRING TEMP REPAIR IAW EO 4427A125, NR 6 FLAP TRACK FAIRING REPLACED. RT INBD AFT FLAP REPLACED, CAM SYS RODS REPLACED. LT OTBD FLAP TEMP REPAIR ACCOMPLISHED IAW EO 1957A169. HARD LANDING PHASE I ACCOMPLISHED. FERRIED TO MX BASE FOR PHASE II ACCOMPLISHMENT.