What was found
RT STRUT DUCT LEAK EICAS MSG. FOUND PRE COOLER EXHAUST FITTING DISCONNECTED BETWEEN PRE COOLER & PRSOV. REPOSITIONED FLANGE & SEAL ASSEMBLY IAW AMM 36-11-15, RAN HIGH POWER IAW AMM 71-00-00, ALL OPERATIONS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT STRUT DUCT LEAK EICAS MSG. FOUND PRE COOLER EXHAUST FITTING DISCONNECTED BETWEEN PRE COOLER & PRSOV. REPOSITIONED FLANGE & SEAL ASSEMBLY IAW AMM 36-11-15, RAN HIGH POWER IAW AMM 71-00-00, ALL OPERATIONS CHECKED GOOD.