What was found
RIGHT ENG IGNITOR 1 STATUS MSG. PLACED ON MEL 74-00-01B, MDDR 67109. SECURED CONNECTOR SOCKETS AT AW0325 CONNECTION SYS TEST IAW AMM CH 74-00-00. RT ENG IGNITOR OPERATES NORMAL MDDR 97109 CLOSED.