What was found
AFTER TAKEOFF HYDRAULIC QTY LOW 4 EICAS MESSAGE. RAN ECL NR 4, SYSTEM OFF. REF LP 812459, ITEM 11. FOUND NR 4 ADP HYDRAULIC PUMP LEAKING. R & R NR 4 ADP AND OPS AND LEAK CHECKS OK IAW MM 29-11-17.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.