What was found
EQUIPMENT OVERHEAT MESSAGE. ACCOMPLISHED QRH SELECRTOR TO STBY FOR 5 MIN THEN OVRD FOR 30 MIN. SELECTOR BACK TO AUTO . OVERHEAT LIGHT EXTINGUISHED . CONT FLIGHT NORMAL. PERFORMED EQUIPMENT COOLING TEST IAW AMM 21-58-00. NO FAULTS FOUND AT THIS STATION.