What was found
POSSIBLE CRACK AT STA 859.5 FRAME INNER CHORD TRANSITION RADIUS LT SIDE. REMOVED DAMAGE, HFEC INSPECTED 13 HOLES, MADE 0.040 INSURANCE CUT, LOCATED AND DRILLED REPAIR ANGLE, FABRICATED REPAIR WASHER, TREATED PRIME REPAIR ANGLES, COLD WORKED HOLE, INSTALLED IAW SRM 51-40-02, B-SB-761-53A0209, EO 753A038, NDT PART G, 51-00-16.