What was found
RT ENGINE PREVIOUS EICAS ANUNCIATOR PERFORMED BITE TEST ON AIR SUPPLY MODULE. FOUND PREVIOUS FAULT RESET BOX. NO FAULTS MSG CLEARED. EICAS. PERFORMED OPS ;IAW AMM 36-11-18, PREVIOUS OPS NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT ENGINE PREVIOUS EICAS ANUNCIATOR PERFORMED BITE TEST ON AIR SUPPLY MODULE. FOUND PREVIOUS FAULT RESET BOX. NO FAULTS MSG CLEARED. EICAS. PERFORMED OPS ;IAW AMM 36-11-18, PREVIOUS OPS NORMAL.