What was found
FWD CARGO CENTER AFT SIDE UNDER FLOOR ELECTRICAL CABLE BS 960 - 980, STRINGER 47L BROKEN. IAW WDM 26-16-17 REV.41 & SWPM 20-30-12 REV.63 SPLICE REPAIRED THE WIRE. IAW AMM 26-16-02-404-010 REV.88 PERFORMED TEST OF EJECTOR AND THE RESULT WAS SATISFACTORY.