What was found
FOUND FLOORBEAM UPPER CHORD CORROSION AT STA 1120 RBL 107~109. REMOVE DAMAGED PART IAW SRM 51-40-02 REV 79 & 2. INSTALL NEW PART IAW SRM 51-40-02 REV 79 AND DWG 65B16046 SH3 REV B & 3. JOB COMPLETED AND CONDITION CHECK NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND FLOORBEAM UPPER CHORD CORROSION AT STA 1120 RBL 107~109. REMOVE DAMAGED PART IAW SRM 51-40-02 REV 79 & 2. INSTALL NEW PART IAW SRM 51-40-02 REV 79 AND DWG 65B16046 SH3 REV B & 3. JOB COMPLETED AND CONDITION CHECK NORMAL.