As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LEFT INBD MAIN FUEL TANK FUELING SHUTOFF VALVE BONDING RESISTANCE CHECK FOUND OUT OF TOLERANCE. THE BONDING JUMPER WAS REMOVED, CLEANED & INSTALLED IAW AMM 20-11-00, REV 120. BONDING RESISTANCE CHECK CARRIED OUT IAW AMM 28-22-11, REV 120 AND FOUND SATISFACTORY.