What was found
RIGHT ENGINE EEC OFF EICAS AND OFF LIGHT ILLUMINATED ON POWER TRANSFER DURING ENGINE START. RESET AND OPS NORMAL FOR FULL FLIGHT, COMPLIED WITH FIM 73-21 FT 805 AND FIM 71-01FT 804 REMOVED AND REPLACED THE RT ENGINE PMC IAW AMM 73-21-02, NO HELP, RE INSTALLED PMC TO RIGHT ENGINE. FUTHER TROUBLE SHOOTING EEC OPS CHECKED GOOD. COMPLIED WITH EEC BITE TEST IAW FIM 71-01 FT 804. REMOVED AND REPLACED THE RIGHT ENGINE, FIXED FAILED SOLENOID IAW AMM 73-21-13 BITE TESTED GOOD, NO FAULTS. PERFORMED ENGINE START & EEC OPS CHECKED NORMAL.