What was found
BS 1329 FRAME FOUND CORRODED BETWEEN STRINGER 19 - 20R, RBL 90, WL 205. BLENDED OUT AND FOUND OUT OF LIMITS IAW SRM 53-00-07-1A-1, FIG 101, ALLOWABLE DAMAGE 1, REV 104. REMOVED AND REPLACED THE FRAME IAW SRM 51-40-02, REV 104.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 1329 FRAME FOUND CORRODED BETWEEN STRINGER 19 - 20R, RBL 90, WL 205. BLENDED OUT AND FOUND OUT OF LIMITS IAW SRM 53-00-07-1A-1, FIG 101, ALLOWABLE DAMAGE 1, REV 104. REMOVED AND REPLACED THE FRAME IAW SRM 51-40-02, REV 104.