What was found
EICAS SHOWS A FWD EQUIPMENT COOL VALVE MESSAGE AND P5 EQUIPMENT COOLING PANEL SHOWS VALUE LIGHT WHEN AIRCRAFT IN AIR MODE. FOUND GROUND EQUIPMENT COOLING EXHAUST VALUE INTERNAL POSITION CIRCUIT NO GOOD. EQUIPMENT COOLING OVERBOARD EXHAUST VALUE REMOVED & REPLACED IAW AMM 21-58-05, REV 121 & TESTED IAW AMM 21-58-05, REV 121, FOUND SATISFACTORY.