What was found
APU ECU FAULTY, EGT HARNESS CIRCUIT NR 2 FAULT LATCHED ON. FOUND HARNESS CONNECTORS FOR EGT CIRCUITS 1 AND 2 CROSSED. CORRECTED THE CONNECTORS IAW SWPM 20-10-11. OPS CHECKED NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU ECU FAULTY, EGT HARNESS CIRCUIT NR 2 FAULT LATCHED ON. FOUND HARNESS CONNECTORS FOR EGT CIRCUITS 1 AND 2 CROSSED. CORRECTED THE CONNECTORS IAW SWPM 20-10-11. OPS CHECKED NORMAL.