What was found
UNABLE TO START APU. OPS CHECK APU IAW FIM 49-11-988, APU OPS CHECKED NORMAL. NO DEFECTS NOTED. START EGT MAX 778, STABLE AT 343 EGT. KVA MAX ELEC AIR LOAD, EGT STABILIZED AT 450 DEGREES.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
UNABLE TO START APU. OPS CHECK APU IAW FIM 49-11-988, APU OPS CHECKED NORMAL. NO DEFECTS NOTED. START EGT MAX 778, STABLE AT 343 EGT. KVA MAX ELEC AIR LOAD, EGT STABILIZED AT 450 DEGREES.