FWD CABIN BS 346, JUST INSIDE OF FWD SERVICE DOOR FLOOR STRAP ANGLE HAS CORROSION WITHIN 6 INCHES OF END CONTINUING TO FLOOR SUPPORT. REMOVED CORROSION FOUND TO BE WITHIN LIMITS IAW SRM 51-40-02, AND 53-00-15-1A-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CABIN BS 346, JUST INSIDE OF FWD SERVICE DOOR FLOOR STRAP ANGLE HAS CORROSION WITHIN 6 INCHES OF END CONTINUING TO FLOOR SUPPORT. REMOVED CORROSION FOUND TO BE WITHIN LIMITS IAW SRM 51-40-02, AND 53-00-15-1A-1.