What was found
AFT CABIN TEMP MESSAGE. REMOVED AND REPLACED AFT TRIM AIR MODULATING VALVE IAW AMM 21-61-07 LEAK AND OPS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CABIN TEMP MESSAGE. REMOVED AND REPLACED AFT TRIM AIR MODULATING VALVE IAW AMM 21-61-07 LEAK AND OPS CHECKED GOOD.