What was found
RIGHT PACK TEMP EICAS ILLUMINATED INTERMITTENTLY DURING CLIMB OUT, LIGHT OUT IN STANDBY. REMOVED AND REPLACED THE RT ACM TEMP CONTROL VALVE OPS & LEAK CHECKED GOOD IAW AMM 21-51-12.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RIGHT PACK TEMP EICAS ILLUMINATED INTERMITTENTLY DURING CLIMB OUT, LIGHT OUT IN STANDBY. REMOVED AND REPLACED THE RT ACM TEMP CONTROL VALVE OPS & LEAK CHECKED GOOD IAW AMM 21-51-12.