NR 1 ENG. PRSOV AIR TEMP SENSOR PRESSURE SWITCH PLASTIC WIRE HOUSING CRACKED AND HAS EXPOSED WIRES. REMOVED AND REPLACED THE NR 1 ENG PRSOV FAN AIR TEMP SENSOR IAW AMM 36-11-17-004-001 AND 36-11-17-404-017. LEAK CHECKED GOOD IAW AMM 36-11-17-404-017 AND BITE TESTED GOOD IAW AMM 36-23-00.