What was found
DURING ENG START DUCT PRESS DROPPED BELOW 10PSI AND N2 ROTATION STAGNATED AT 14.9%. REMOVED AND REPLACED IGV ACTUATOR I.A.W AMM 49-52-02 OPS CHECK C/W , APU OPERATES NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING ENG START DUCT PRESS DROPPED BELOW 10PSI AND N2 ROTATION STAGNATED AT 14.9%. REMOVED AND REPLACED IGV ACTUATOR I.A.W AMM 49-52-02 OPS CHECK C/W , APU OPERATES NORMAL.