What was found
APU DUCT PRESSURE DROPPED TO 15 PSI DURING START. REMOVED AND REPLACED SURGE CONTROL VALVE IAW AMM 49-53-01, OPS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU DUCT PRESSURE DROPPED TO 15 PSI DURING START. REMOVED AND REPLACED SURGE CONTROL VALVE IAW AMM 49-53-01, OPS CHECKED GOOD.