What was found
NR 1 A/C PACK AND CLIMB TROUGH 4000, LT DUCT PRESSURE 3300, RT DUCT PRESSURE, 1500. DID NOT QUIT DOWN UNTIL APPROCH FL 240. PRESSURE CONSISTANT THROUGHT FLIGHT AT 3300 - 1500. R & R PRV CONTROLLER IAW AMM 36-11-14, OPS CHECKED GOOD, LEAK CHECKED MUSCLE AIR LINE VALVE TO CONTROLLER. ALL CHECKED GOOD, ENGINE RUNS IAW AMM 71-00-00. OK FOR SERVICES.