What was found
AT ROTATION & DURING INITIAL CLIMB THROUGH 10.000 FT, RT FWD FUEL PUMP EICAS MESSAGE, MESSAGE EXTINGUISHED AS QRH WAS STARTED, DID NOT PRESSURE INDICATION ON PUMP, AFTER ROTATION & DURING CLIMB, FUEL CONFIGURATION MESSAGE , LEFT TANK INDICATED 3000 LBS LESS THAN RIGHT , MESSAGE EXTINGUISHED AT SAME TIME RT FWD FUEL PUMP MESSAGE DID. PERFORMED FIM TASK 28-41 FT 854, FQIS BITE TESTED GOOD. NO FAULTS NOTED, PERFORMED OPERATIONAL TEST OF FWD RIGHT BOOST PUMP IAWAMM 28-22-00, NO FAULTS NOTED, NO CIRCUIT BREAKER TRIPPED.