What was found
LT VERTICAL STAB T/E PANEL SUPPORT BEAM AT RUDDER STA 382.4, FOUND CRACKED. SUPPORT BEAM CAP ANGLE WAS REPAIRED IAW SRM 55-30-13-2R-2, REPAIR 2, FIG 202.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LT VERTICAL STAB T/E PANEL SUPPORT BEAM AT RUDDER STA 382.4, FOUND CRACKED. SUPPORT BEAM CAP ANGLE WAS REPAIRED IAW SRM 55-30-13-2R-2, REPAIR 2, FIG 202.