What was found
IN FLIGHT ADJUSTED FWD CABIN TEMPERATURE TO WARM. FWD CABIN TEMPERATURE EICAS. REMOVED AND REPLACED FWD CABIN TRIM AIR MODULATING IAW AMM 21-61-07. RESET CIRCUIT BREAKERS R24, R25, R27 OPS CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
IN FLIGHT ADJUSTED FWD CABIN TEMPERATURE TO WARM. FWD CABIN TEMPERATURE EICAS. REMOVED AND REPLACED FWD CABIN TRIM AIR MODULATING IAW AMM 21-61-07. RESET CIRCUIT BREAKERS R24, R25, R27 OPS CHECK GOOD.