What was found
FOUND TWO DENTS ADJACENT TO EACH OTHER AT RIGHT UPPER HALF OF FUSELAGE APPROX AT STA 1197 BETWEEN STRINGER 3R-4R, BELOW JOINT LAP. REMOVED 3EA FASTENERS BETWEEN 1197+88 AND STA 1197+132 STR 2R AND 4R, HFEC AREA NO CRACKS NOTED, RE-INSTALLED 3EA FASTENERS AT AREA IAW EA18144 REV IR.