As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ATA 53-10, EO 4453A024 PART 1 DURING ACCOMPLISHMENT OF HFEC OPEN HOLE INSPECTION AT BS 2231 STR 16L, FOUND 03 EA CRACK INDICATION AT LOWER MOST FWD FASTENER HOLE, ON 2ND AND 3RD LAYER AT 3 O'CLOCK AND 6 O'CLOCK POSITION AS MARKED. 03 EA CRACKED FASTENER HOLE AT BS 2231 STR S-16L REPAIRED AS PER EN 1115-18 REV '-'.