What was found
APU FAULTY CAUTION MSG ON START AFTER LANDING. APU ECU BITE FOUND MSG START ABORTED, PERFORMED TROUBLE SHOOTING IAW FIM 49-11, FT 989. FOUND IGV ACTUATOR MOUNTING HARDWERE LOOSE, SECURED HARDWARE IAW AMM 49-52-02. PERFORMED 3 SUCCESFUL STARTS, NO DEFECT NOTED A THIS TIME.